Take Our Survey Contact Us LinkedIn Twitter YouTube Channel

HES Series - Energy Saving Refrigerated Compressed Air Dryers 3750-12500 scfm

Product Type:
Air And Gas Treatment / Refrigerated Compressed Air Dryers

Utilizing the latest technological advancements, HES Series refrigerated dryers offer a new way of thinking and innovative approach to efficiently treat compressed air.

Features

Save, Optimize Performance Energy!

The HES Series significantly lowers total cost of operation by consuming electrical power (kWh) in direct proportion to real-time demand.

Meeting the Needs of Today...

The HES Series features modular construction offering multiple design variations for flexible arrangement.

...Anticipating Opportunity for Tomorrow

Redundancy in critical components offers fault-tolerant operation, delivering optimal system reliability. The HES series offers back-up drying protection presenting alternative drying capability in the presence of component failure.

Specifications
MODEL FLOW
RATE
SCFM1
FLOW
RATE
NM3/H
NUMBER
OF
MODULES2
REFRIGERANT
COMPRESSOR
HORSEPOWER3
AVAILABLE
VOLTAGES4
OPERATING
POWER
CONSUMPTION5
KW
IN/OUT
CONNECTION
FLG
WATER
FLOW
@ 85°F
GPM
WATER
SU PPLY
CONNECTION
NPT (F)
HES3750 3750 6371 2 (1) 10 + (1) 6 Standard:
460/3/60


Optional:
575/3/60;
230/3/60
15.8 8" 19 2.5"
HES5000 5000 8495 2 (2) 10 19.8 8" 26 2.5"
HES6250 6250 10619 3 (2) 10 + (1) 6 25.7 10" 32 2.5"
HES7500 7500 12743 3 (3) 10 29.6 10" 39 2.5"
HES8750 8750 14866 4 (3) 10 + (1) 6 35.6 12" 45 2.5"
HES10000 10000 16990 4 (4) 10 39.6 12" 52 2.5"
HES11250 11250 19114 5 (4) 10 + (1) 6 45.5 12" 58 2.5"
HES12500 12500 21238 5 (5) 10 49.5 12" 65 2.5"


Dryers meet agency approvals: CSA (CAN /CSA-C22.2 No.236-95) - Heating and Cooling Equipment and U L Standard No. 1995.
Canadian Registration Numbers- standard separator vessel and optional cold coalescing housing.
1 Rated Flow Capacity - Conditions for rating dryers are in accordance with ISO 7183 (option A2) working conditions: inlet air temperature 100ºF (38ºC), inlet air pressure 100 psig (6.9 bar), cooling water temperature 85ºF (29ºC), 100% saturated air
2 Individual modules are combined in 1250 scfm and 2500 scfm increments to provide the desired flow capacity.
3 Digital scroll compressors utilize environmentally friendly R404a refrigerant.
4 Optional Voltages: 575/3/60 requirements utilize module-mounted transformers to step-down incoming power to 460/3/60; 230/3/60 requirements utilize module-mounted transformers to step-up to 460/3/60.
5 Full flow kW value operating on 460/3/60 Hz power supply.

 

Maximum Working
Pressure
Minimum Working
Pressure
Maximum Inlet Air
Temperature
Minimum Inlet Air
Temperature
Maximum Ambient Air
Temperature
Minimum Ambient Air
Temperature
psig barg psig barg °F °C °F °C °F °C °F °C
232 16 30 2 130 54 40 4 110 43 40 4
Dimensions

HES3750

MODEL DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HES3750 96 84 81 3,391

HES5000

MODEL DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HES5000 96 84 81 3,474

HES6250

MODEL DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HES6250 97 125 81 5,412

HES7500

MODEL DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HES7500 97 125 81 5,624

HES8750

MODEL DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HES8750 99 163 81 7,664

HES10000

MODEL DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HES10000 99 163 81 7,876

HES11250

MODEL DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HES11250 99 202 81 9,623

HES12500

MODEL DIMENSIONS (INCHES) WEIGHT
LBS
H W D
HES12500 99 202 81 9,836
Downloads
Brochure
HES Series 3750-12500 scfm US