D4 Series - Double Seat Mixproof Valves

Product Type(s) : Double Seat Valves
Description :

Offers reliable separation of fluids and an ultra-hygienic option for enhanced cleanability..

WHERE TO BUY

FEATURES

The next generation of mixproof valve technology is the result of continued development from both APV and Waukesha Cherry-Burrell process technologies. Used for the reliable separation of dissimilar fluids, the D4 Series helps fulfill today's customer demands for production flexibility, increased productivity, rapid return on investment (ROI), and improved product quality across the Food & Beverage, Dairy, Personal Care and Brewing process industries.


High value, Low life cycle costs:

  • Tiered model range helps to increase ROI and align with customer budgets
  • "All In" standard features provide exceptional value
  • Reduced inventory costs with same seal kit used on multiple size ranges such as one kit for 1.5" - 3.0" sizes
  • Reduced CIP losses improve cost savings
  • Low air consumption and air supply requirements
  • Long housing ports ease manifold building
  • Integrated shaft seal flush reduces need for external piping
  • Replacement insert available to easily upgrade existing installations


Reliable performance:

  • Fully balanced design helps to prevent hydraulic blocking, withstand pressure spikes, and enables flexible flow direction without slamming
  • Light overall weight helps support handling without lifting tools
  • Slim stainless actuator is fully enclosed to prevent fluid ingress
  • Range of control units and bus communication for automated operation
  • No compressed air needed for removal and servicing


Cleanability:

  • Designed to the latest hygienic standards
  • Standard cavity spray cleaning
  • Extensive cleaning of product contact seals

 

Benefits:

 

Valve Type   Feature Benefit
D4 1 Radial seal design for reduced losses of product fluids during switching - Product cost savings

-Cleaner operating environment
Choice of seat lifting (SL) or non-seat lifting (NSL) actuator Modular design to fit a wide range of cleanability and functionality needs
Hazardous rated options available (ATEX Zone 1 or 2) Provides safe operation in critical applications
DA4 2 Integrated upper and lower shaft seal and balancer flushing -Extensive cleaning of product contact surfaces

-Helps to reduce external flush piping
3 Metal orficies control CIP flow during seat lift Reduces chemical and water loss consumption
Replacement insert fits into existing DA3+ housing Easy upgrade to next generation with improved features
D4 and DA4 4 Open yoke design -Reduces heat transfer from product zone into actuator

- Provides visual leak detection of damaged shaft seals

- Safety guard provided to reduce pinch points
5 Bolted flange connection for housing insert - Heavy-duty, secure connection

- Reliable and controlled assembly and disassembly of valve insert
6 Long ports to ease manifold building Helps to reduce spool pieces and welds to ease manifold building
Only two seal kit sizes used on entire range: DN40-DN65 (1.5" - 3.0") and DN80-DN100(4.0") Reduces inventory and maintenance costs
Fully integrated sensors to detect all critical positions - No external wires exposed to wash-down and mishandling

- Extra security to monitor seat positions during cleaning
No compressed air required for servicing Easy and efficient maintenance
7 Balanced upper and lower shafts (as standard) - No hydraulic blocking

- Resistant against pressure spikes

- Flexibility in either flow direction through the valve (top-to-bottom or bottom-to-top) without water hammering
Reduced cleaning fluid losses to drain - Chemical and water savings

- Cleaner environment due to fewer chemicals and fluids spilling to the floor
8 Large separation cavity drain port Less product risk and prevention of pressure build-up that could cause cross-contamination
9 Flush cavity spray fixed connection (as standard) - Enhanced cleaning

- Removal of residual media in separation cavity when full CIP is not readily available

- Hard-piped flush can be used without need to be removed during valve maintenance
Light overall weight Easier handling for maintenance
Theory of Operation

Double seat mixproof valves are used to efficiently process two different fluids (typically product and CIP) through the valve simultaneously. The mixproof design has two seats which isolate the upper and lower pipe lines when the valve is in the fail-safe closed position. The atmospheric vent cavity in between the seats creates a path for any leakage should the seals fail as well as a drain for CIP solution during seat cleaning. An external CIP spray flush is included to provide enhanced cleaning of the leakage and vent cavity while the valve is closed or open during production.



Valve Closed

Optional Lower Seat Clean

Valve Open



Optional Upper Seat Clean

DIMENSIONS & SPECIFICATIONS

D4 SERIES




DIMENSIONS INCH A A1 A2 B øDa øDi F H L L1 L2 X* Y*
1.5 19.1 22.4 24.9 4.7 1.5 1.4 4.9 2.5 26.3 29.5   32.3 7.8
2.0 19.2 22.5 25 4.9 2.0 1.9 4.9 3.0 27.1 30.4   32.7 8.5
2.5 19.4 22.6 25.1 5.2 2.5 2.4 4.9 3.4 27.9 31.2   33.1 9.2
3.0 19.6 22.9 25.4 5.4 3.0 2.9 4.9 3.9 28.9 32.1   33.5 9.9
4.0 23.4 26.7 29.2 6.1 4.0 3.8 5.6 4.9 34.4 37.7   33.1 11.9
6.0 28.6 31.3 33.8 7.6 5.8 6.0 5.9 6.9 43.1 45.7   42.5 15.4
2.0 Sh5 19.3 22.6 25.1 5.1 2.4 2.2 4.9 3.2 27.6 30.9   29.5 9.0
3.0 Sh5 23.0 26.3 28.8 5.8 3.5 3.3 5.6 4.3 33.2 36.4   35.4 11.1
4.0 Sh5 26.4 29.6 32.1 6.7 4.5 4.3 5.9 5.3 38.4 41.7   40.2 13.0
6.0 Sh5 28.8 31.5 34 7.9 6.6 6.4 5.9 7.4 44.1 46.8   42.7 16.1

*Minimum installation and valve insert removal dimensions

NOTE: Add the following approximate dimension to F for each clamp port connection 0.86" for valve sizes 1.5" - 2.0" and 1.0" for valve size 2.5" - 4".

D4 SL SERIES




DIMENSIONS INCH A A1 A2 B øDa øDi F H L L1 L2 X* Y*
1.5 20.7 24.0 26.5 4.7 1.5 1.4 4.9 2.5 27.9 31.1 33.6 34.3 7.8
2.0 20.8 24.1 26.6 4.9 2.0 1.9 4.9 3.0 28.7 32.0 34.5 34.6 8.5
2.5 21.0 24.3 26.8 5.2 2.5 2.4 4.9 3.4 29.5 32.8 35.3 35.0 9.2
3.0 21.3 24.5 27 5.4 3.0 2.9 4.9 3.9 30.5 33.8 36.3 35.4 9.9
4.0 24.8 28.0 30.5 6.1 4.0 3.8 5.6 4.9 35.8 39.1 41.6 39.0 11.9
6.0 28.6 31.3 33.8 7.6 5.8 6.0 5.9 6.9 43.1 45.7 48.2 42.5 15.4
2.0 Sh5 20.9 24.2 26.7 5.1 2.4 2.2 4.9 3.2 29.2 32.5 35 31.1 9.0
3.0 Sh5 24.4 27.7 30.2 5.8 3.5 3.3 5.6 4.3 34.6 37.8 40.3 36.8 11.1
4.0 Sh5 26.4 29.6 32.1 6.7 4.5 4.3 5.9 5.3 38.4 41.7 44.2 40.2 13.0
6.0 Sh5 28.8 31.5 34 7.9 6.6 6.4 5.9 7.4 44.1 46.8 49.3 42.7 16.1

*Minimum installation and valve insert removal dimensions

NOTE: Add the following approximate dimension to F for each clamp port connection 0.86" for valve sizes 1.5" - 2.0" and 1.0" for valve size 2.5" - 4".

DA4 SERIES




DIMENSIONS INCH A A1 A2 B øDa øDi F H L L1 L2 X* Y*
1.5 23.1 26.4 28.9 4.7 1.5 1.4 4.9 2.5 30.3 33.6 36.1 36.6 7.8
2.0 23.4 26.7 29.2 4.9 2.0 1.9 4.9 3.0 31.3 34.5 37 37.0 8.5
2.5 23.5 26.8 29.3 5.2 2.5 2.4 4.9 3.4 32.1 35.3 37.8 37.4 9.2
3.0 23.8 27.0 29.5 5.4 3.0 2.9 4.9 3.9 33.0 36.3 38.8 37.8 9.9
4.0 27.1 30.4 32.9 6.1 4.0 3.8 5.6 4.9 38.1 41.4 43.9 41.3 11.9

*Minimum installation and valve insert removal dimensions

NOTE: Add the following approximate dimension to F for each clamp port connection 0.86" for valve sizes 1.5" - 2.0" and 1.0" for valve size 2.5" - 4".

Sizes: 

  • OD Tube 1.5" - 6"
  • Schedule 5 Pipe 2" - 6
  • Others on request

Product Wetted Parts: 1.4404/AISI 316L Other stainless steel parts 1.4301/AISI 304 Non-Product Wetted Parts:  AISI 304 / 1.4301 Seal Materials (All seals comply with FDA requirement): 

  • Standard EPDM
  • Optional: HNBR, FPM

Surfaces:

  • Inside: Ra 32 µ-in (0.8 µm) with Electro-polish
  • Outside: Glass -blasted, satin finish

Required Air Pressure: 73 psi (5 bar), valve normally closed

OPTIONS & PERFORMANCE

Housing Combinations

 

Shut-off Valves

Mixproof shut-off valves are used to keep incompatible products from mixing at pipe junctions, or to simply shut flow from an upper to lower line within a valve matrix.

Divert Valves

Mixproof divert valves are used for distributing liquid from one pipeline into two others (or vice versa)

 


 

Control Units

 

CU4 & CU4plus Series - Benefits

  • Automated control and position monitoring for reliable processing
  • Reduces compressed air and electrical connections
  • Helps reduce external solenoid valve cabinets
  • Accelerates valve response time
  • Innovative seat lift detection is fully integrated without need for external sensor wiring to provide additional position monitoring
  • Reliability and long service life - robust clamp connection, reinforced stainless steel air coupling threads to avoid air leakages, and water tight seals
  • Ease of operation - contains manual override solenoids and adjustment screw to throttle air flow to actuator to ensure optimal opening and closing
  • Clarity - clear and bright indication of valve position - 5 diodes in LED panel and convenient location
  • Standardization - same control top used on various SPX FLOW valve lines, offers common look and controls interface
  • NEMA6/IP67/IP69k*, washdown rating
  • ATEX / IECEx rated environments

 

CONNECTOR OPTIONS

S/O Cord Grip for hard wire (std)

M12 4-pin connector (optional)

POSITION INDICATION

CU4: 2 internal feedback sensors for valve open/valve closed position detection
CU4plus: Automatic teaching of all positions with press of single button
CU4plus: Detection of all positions (open, close, upper/lower seat lifts)

INTERFACE OPTIONS

24V DC Direct Connect

AS-i Field Bus Card

SOLENOID VALVES

24V DC

Select 1 (non seat lift) or 3 Solenoids (seat lift)

*IP69K compliance achieved by modification of the exhaust


 

8681 Control Unit - Benefits

  • Contact free position sensor including (3) programmable feedback signals
  • Positions easily taught via intuitive push buttons or Autotune feature to ensure quick & easy set-up
  • Ultra-bright 360° visual LED position indication with adjustable red, yellow, & green color assignments provide clarity from all points of view and avoid confusion
  • Manual override and air throttle adjustable solenoids to assist start-up, maintenance, and troubleshooting
  • Up to IP69K washdown rating available (IP65/67 as standard) for high washdown environments
  • Built-in microcontroller tracks cycles and alerts operator when preventive maintenance is required
  • Simple and robust stainless steel adapter & chemically resistant polycarbonate head
  • Supplied by industry leading Burkert Fluid Controls

 

CONNECTOR OPTIONS

Quick Disconnect Pin Connector

POSITION INDICATION

(3) programmable position sensors in control top

INTERFACE OPTIONS

AS-i Field Bus Card

DeviceNet™ Field Bus Network Card

SOLENOID VALVES

24V DC

Manual override and air throttle adjustment

Up to (3) available in control top

Pressure Ratings:

  • Operating Pressure:  Maximum line pressure: 145 psi (10 bar)

Maximum Temperature:

  • EPDM & HNR: 275ºF / 135ºC (short time 284ºF / 140ºC)
  • FPM 275ºF / 135ºC
  • Not to be used for steam

Sterilization Temperature:

  • EPDM & HNBR: (short time) 284ºF / 140ºC

VIDEOS

Downloads

}